The same hardware requirements as for SIMATIC STEP 7 V5.6 itself apply to the host operating systems. There can be restrictions on the STEP 7 online functions.
#Step 7 v5.6 windows 7 64bit install#
You can use the following guest operating systems within the selected virtualization platform to install SIMATIC STEP 7 V5.6: To do so, use one of the following virtualization platforms:
#Step 7 v5.6 windows 7 64bit software#
You can install the SIMATIC STEP 7 V5.6 software package in a virtual machine. The only limitation is the inability to write data simultaneously by several developers. STEP 7 provides parallel work on the same project by several developers. To be able to connect programmable controllers, the computer must be equipped with an MPI / Profibus card or a PC / MPI / Profibus adapter and a connecting cable.
#Step 7 v5.6 windows 7 64bit windows 10#
It can be delivered as a standalone software package for personal computers running Windows 7 / Windows 10 operating systems. STEP 7 is included with the SIMATIC Field PG.
![step 7 v5.6 windows 7 64bit step 7 v5.6 windows 7 64bit](https://newtry225.weebly.com/uploads/1/2/4/8/124864439/690735803.jpg)
#Step 7 v5.6 windows 7 64bit drivers#
Apparently my Siemens USB drivers did not install properly. It was a big ordeal, took me half a day to figure it out. I used an old USB-MPI adapter I have from many moons ago to connect to it. Have you properly set the PROFIBUS ADRESS in the HW configuration ? Have you checked the PG/PC interface works ? So am I barking up the wrong tree or what? Do I need (In addition to Step7 5.6) Step7 V5.2 SP1 in order to upload from this PLC? Is this like RSLogix5000 where you need to have installed many many old legacy versions of the same software in order to service the whole array of existing machines? Or am I having some other problem? However I do not believe that the CPU317-2 DP is fully installed or fully compatible because when I attempt to create a new project based on that PLC, it is not available from the New Project Wizard.
#Step 7 v5.6 windows 7 64bit update#
Cannot install over a HW update supplied with the STEP7 Version"). According to the datasheet for that CPU I think I what I have should work.Īccording to my HWUpdates it seems I have this in my library already and cannot overwrite/reinstall that specific update (else I get an error: "Selection not possible. I have downloaded all the HWUpdates but some I cannot install because it says "supplied."įor example yesterday I attempted to upload from a CPU317-2 DP (6ES7 317-2AK14-0AB0) and it crashed every time.
![step 7 v5.6 windows 7 64bit step 7 v5.6 windows 7 64bit](https://rahim-soft.com/wp-content/uploads/2019/09/Siemens-SIMATIC-STEP-7-1.jpg)
My research into the cause loosely points at the PLC being an incompatible hardware with my 5.6 software. In Step7 v.5.6 I have experienced on many machines (actually all the machines I have tried so far) that the software will crash when I attempt to upload from the PLC. I am currently evaluating (trial version) of Step7 5.6 and TIA Portal V.14.1, in an effort to determine what we need to buy in order to support all our machines. We have dozens of machines with Siemens PLCs ranging from 20yrs old to brand new. My employer has relied on the OEM for PLC support until now, and now it's my job to take over.
![step 7 v5.6 windows 7 64bit step 7 v5.6 windows 7 64bit](https://3.bp.blogspot.com/-ekjiRNqwy8U/WaEkXMGfy2I/AAAAAAAAEEk/VF_zrQvsMLQ4ajQqc_oIJt5qIqkDaqjwgCLcBGAs/s1600/8.png)
I am experienced with many PLC platforms except Siemens.